
Closed
Posted
Paid on delivery
Need Structural Repair Drawings and needed structural repair calcs to do the following. ONLY BID AFTER REVIEWING IMAGES OF THE CONCRETE SLAB, RAILING DAMAGES. Do NOT BID IF YOU DON'T HAVE A PORTFOLIO of simlar work in USA. Project located in Florida with with speeds at 139MPH zone. FBC 2023, ASCE-7-22 Wind Loads. Balcony and walkway railing must comply with FBC 2023 requirements. Existing second floor walkway railing are wooden with delamination and damage, so must be replaced in full or partial. Stairs railing are metal with moderate corrosion, so must be repalced. Seconf floor balconies show some corrosion damage to the long span bars, cracked and spalling concrete for balcony slab, and support beam. Partition CMU balcony walls also show corroded vertical rebar, need repairs and waterproofing details. Second floor concrete balconies with minor repairs, some longitudnal rebar show minor corrosion. Second floor balconies existing wood railing replacement with SYP wood railing per FBC 2023. Stairs railing replacement drawings from first to second floor walkway design and drawings. The building is apartment building with CMU construction, concrete foundation and floor slabs, wood roof frmaing for main building. NO REPAIRS NEEDED TO MAIN BUILDING. Structural calculations for repairs and/or replacement for walkway and stair railings with drawings needed. Calcs for balcony slab/cantilever beams corroded rebars with complete details needed. Must have concrete, wood, metal stair railing repair, retrofit and replacement experience in USA. Shall be a P.E , who can possibly sign his own calcs, and drawings. Time available 2 weeks.
Project ID: 40796653
41 proposals
Remote project
Active 6 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
41 freelancers are bidding on average $972 USD for this job

Your project needs permit-ready structural documentation for Florida’s high-wind environment, and my 12 years of architectural and CAD design experience can support the detailed repair drawings required for the balconies, walkways, and stair railings. I work with AutoCAD and Building Architecture to produce clear, accurate construction drawings for repair and replacement work. I can prepare coordinated drawings showing the affected concrete slabs, cantilever beams, CMU balcony walls, wood railing replacements, metal stair railings, concrete repairs, corrosion treatment, waterproofing details, and required connection information. The drawings can be developed around the stated FBC 2023 and ASCE 7-22 requirements, with structural calculations coordinated for review and approval by the project’s Florida-licensed P.E. where required. My focus is precise, buildable CAD documentation that contractors and reviewers can understand easily. I would be glad to contribute my drafting and architectural expertise to this Florida balcony and railing repair package.
$750 USD in 7 days
7.4
7.4

As a Professional Engineer (P.E.) with 10 years of structural engineering and forensic repair experience across the United States, I specialize in coastal structural restoration, reinforced concrete spall repairs per ICRI standards, CMU remediation, and railing replacements designed for high-velocity hurricane zones under the Florida Building Code (FBC 2023) and ASCE 7-22 (139 MPH wind speeds). Please share site measurements, and any existing structural drawings of the balcony slabs, support beams, and stairs so we can review the conditions and get started right away. Best regards, Ghullam Hussain, P.E.
$1,100 USD in 6 days
7.6
7.6

Your project requires a careful structural drafting professional familiar with concrete, CMU, wood, and metal components, and AutoCAD is my core technical skill for producing clear construction and repair drawings. I can support the preparation of detailed balcony, walkway, and stair-railing plans covering damaged concrete, corroded reinforcement, railing replacement, and waterproofing-related details. My broader engineering and architectural experience includes construction drawings, housing design, structural 2D/3D modeling, and work with tools such as Revit, Tekla, CATIA, and Abaqus. This allows me to coordinate repair details accurately across balcony slabs, cantilever beams, CMU partitions, wood railings, and metal stair systems while keeping the drawings organized for review against the Florida Building Code and applicable wind-load requirements. I can also provide a professional AutoCAD drawing set based on the supplied site images and existing conditions. Please note that PE review, calculations, and signing must be completed by a properly licensed Florida Professional Engineer; I can prepare and coordinate the technical drawing package for that review. Choose me for precise, well-presented repair and replacement drawings.
$758 USD in 3 days
7.5
7.5

Hello there, This is Sajjad Khan. I am an Architect with more than 6 years of experience in my field in Design and Visualization, MEP, Structural etc. I am experienced in Revit, Rhino, Twinmotion, 3ds Max, AutoCAD, SketchUp, Lumion, D5 Render and Blender as well. I have recent experience in similar projects also. It’s an interesting project and I am really excited to start working on it. Please Get in Touch with me for further discussion on the project.. Thanks Sajjad Khan
$1,000 USD in 10 days
6.6
6.6

Hello, Live Experts LLC offers more than a decade of multidisciplinary engineering and technical delivery experience, including electrical and mechanical engineering support for real-world hardware and built-environment needs. That practical engineering background is relevant to documenting repair and replacement work involving concrete, corroded reinforcement, wood components, and metal railings. Our team is experienced in translating complex physical conditions into clear, production-ready technical documentation, with an emphasis on practical implementation, reliable details, and clear communication. We can support the preparation of structural repair drawings and calculations for the balcony slabs, cantilever beams, CMU balcony walls, walkways, and stair railings described in your project, while accounting for the stated Florida location and wind-load requirements. Because this project requires a Florida P.E. capable of signing and sealing the final documents, the responsible professional’s licensing and authority to seal the work must be verified before award. I would welcome the opportunity to apply our engineering support capabilities to this repair package and help deliver clear, coordinated documentation within the stated timeframe. Thanks!
$1,500 USD in 2 days
6.1
6.1

Hello, I am a structural engineer Have 20 years of experience. I have worked a lot with repairs Have FL PE license I can help you with the design and permit/construction drawings. I use Revit or Autocad. Thanks!
$1,125 USD in 9 days
6.1
6.1

How are you? Your project matches well with my skills. Please check my profile. https://www.freelancer.com/u/lamvanduong I'll provide all drawing sets and wonderful result such as PDF, DWG(2D drawings), rendering images and BIM(3D model). I have full experience in Architectural BIM modeling, MEP design, structural design, civil engineering and drawing by using revit, Archicad, Chief architect, sketchup and cad , etc. I'll use your country building code to permit. Let's discuss more about project and start together. Best regards
$750 USD in 5 days
5.7
5.7

Hello, I have experience preparing structural repair drawings for concrete balconies, corroded reinforcement, and wood and metal railing systems on U.S. residential buildings. I'm familiar with FBC 2023 and ASCE 7-22 requirements, including structural repairs and railing design for 139 mph wind conditions. I'm not personally licensed in Florida, but I work with a licensed Florida PE who can independently review and seal compliant drawings. I'll first review your damage photos and existing plans to assess concrete deterioration, reinforcement corrosion, and railing conditions. I'll prepare balcony slab, beam, and CMU repair details, waterproofing specifications, SYP wood railing replacements, metal stair railing drawings, and supporting structural calculations. I'll coordinate the PE's review and seal and target delivery of permit-ready drawings within two weeks, subject to the assessment findings. Thanks for reading my proposal. Edwin
$1,000 USD in 7 days
5.4
5.4

Hello, Gridline Digital Studio specializes in construction-ready permit and structural documentation for US projects, including accurate as-built drawings from scans, legacy plans, PDFs, and site photos. That experience is relevant to documenting the damaged balconies, walkways, stairs, CMU walls, slabs, beams, and existing railings clearly for repair or replacement design. I can produce coordinated Revit/AutoCAD drawing sets and native RVT, DWG, and PDF files, with milestone delivery and revision-tracked issues to keep the documentation organized. However, the profile does not identify a licensed Florida P.E. or structural engineering experience, so I cannot accurately claim authority to prepare or sign the required FBC 2023 / ASCE 7-22 calculations. I can support the appointed P.E. with precise drafting, BIM coordination, and construction details, while the engineering calculations, review, and professional seal are completed by the qualified Florida engineer. I would be glad to provide dependable drafting and documentation support for this repair package. Thanks!
$1,250 USD in 10 days
4.9
4.9

Hi there ? I have extensive experience using Revit, Chief architect, Autocad and archicad for architectural and MEP modeling, including creating detailed BIM models, floor plans, and construction documentation. I can ensure your project is accurately modeled with full parametric functionality for easy updates. I can start with an initial model draft for your review. Looking forward to collaborating! thank you
$750 USD in 7 days
4.1
4.1

Hello, We can assist with the CAD repair and retrofit drawing package for the balcony slabs, cantilever beams, CMU balcony walls, and walkway and stair railings. Our scope can include existing-condition documentation, repair details, material specifications, and coordinated structural drawings. Could you share the damage photographs and available structural drawings for an initial scope review? Please note that Florida PE review, calculations, and signed/sealed documents must be provided by a locally licensed Professional Engineer. We cannot claim that qualification or provide a US PE seal. Best regards, Rahul Buildtrix Studio
$755 USD in 7 days
4.1
4.1

I have 13 years of experience in engineering design workflows, CAD documentation, and technical problem-solving. After reviewing your photos, I can see visible corrosion at railing connections, deterioration and spalling of concrete around balcony support areas, and damaged railing components that warrant careful structural assessment. I can help develop a coordinated repair package covering balcony slab and cantilever beam rehabilitation, corroded reinforcement, CMU balcony wall repairs, waterproofing details, wood railing replacement, and metal stair railing replacement. The drawings and calculations would be organized around the 2023 Florida Building Code and ASCE 7-22 requirements, including the specified 139 mph wind zone. My priority is to provide clear, practical repair details, material specifications, connection requirements, and calculation documentation that can be reviewed for permitting. I understand the two-week deadline and can work toward it once the scope, existing drawings, site dimensions, and available inspection information are confirmed. Because this project requires Florida-specific structural engineering and potentially signed and sealed documents, the final calculations and permit drawings must be completed or reviewed and sealed by a Florida-licensed Professional Engineer authorized to take responsibility for the work. I would also be happy to coordinate the drafting and documentation with that engineer.
$750 USD in 1 day
3.8
3.8

Hi, I've reviewed your requirements and all of the photos. Two things stood out. The stair post bases look worse than moderate corrosion, with visible section loss at the base plate. The balcony beam ends also show spalling and exposed rebar around older patches, which suggests the damage is repeating. I'd have both checked early, since loose concrete sits above the patios and the railing bases are a safety item. My approach Design and calculations :This covers the balcony slab and cantilever beam checks with the measured rebar loss, plus the guard and handrail design to FBC 2023 and ASCE 7-22 at 139 mph. I'll pay close attention to post anchorage at the slab edge, as it's usually the governing detail. Deliverables - Repair plans and details for the concrete and CMU, including rebar repair and waterproofing - SYP balcony railing drawings - Walkway and stair railing replacement drawings - Structural calculations Three quick questions - How many balconies and stairs are included? - Should the stair and walkway railings be galvanized steel or aluminum? - Do you have a contractor who can collect the field data? - The rust streaks along the stair concrete are also worth a look, as they may not be coming from the railing alone. I can check them while the rail work is being designed. Best regards, Steven
$1,000 USD in 10 days
3.1
3.1

Hi, good day. I understand this project requires a comprehensive structural repair package for a Florida apartment building, addressing deteriorated concrete balcony slabs, cantilever beams, corroded reinforcing steel, CMU balcony walls, and damaged wood and metal railings. I can help prepare detailed repair and replacement drawings with supporting calculations, including concrete restoration, rebar treatment, waterproofing, railing connections, and wind-load design in accordance with FBC 2023 and ASCE 7-22. The existing damage photographs must be reviewed before defining the repair scope, and final engineering documents must be reviewed and sealed by a qualified Florida-licensed PE with relevant repair experience. Do the supplied photographs clearly show the extent of concrete spalling, exposed rebar corrosion, and railing connection damage? Best
$1,500 USD in 7 days
0.6
0.6

Hello, As a licensed Professional Engineer with over 16 years of experience in civil, structural, and MEP engineering, I can prepare code-compliant repair calculations and construction drawings for your Florida balconies, walkways, and stairs. My structural background includes wood, steel, and concrete design, directly matching the damaged railing systems, corroded reinforcing steel, spalling concrete, CMU balcony walls, and cantilevered balcony elements described. I prepare detailed engineering calculations, repair and retrofit details, and permit-ready construction documents using AutoCAD and Autodesk Revit. My experience with U.S. building codes and permitting requirements supports evaluation under FBC 2023 and ASCE 7-22, including the stated 139 mph wind zone and required railing design criteria. As a licensed P.E., I can provide stamped drawings where required, subject to Florida licensing and project requirements. I am ready to review the condition images and deliver a coordinated structural repair package within your two-week timeframe. Choose me for a technically sound, permit-focused solution for this project. Thanks!
$750 USD in 5 days
0.0
0.0

Hello, As a Licensed Professional Engineer providing structural calculations, engineering details, and permit-ready CAD documentation, I am well suited to prepare the repair and replacement package for your Florida apartment building. My structural work includes balconies, decks, additions, foundations, beams, columns, load-bearing elements, and complete framing documentation, directly relevant to the damaged balcony slabs, cantilever beams, CMU partitions, walkways, and stair railings. I can develop coordinated structural repair drawings and calculations covering the railing replacements, concrete spalling and corrosion repairs, rebar-related conditions, waterproofing details, and SYP wood railing design. My experience with construction and permit drawing packages, code-compliance coordination, detailed AutoCAD documentation, and multifamily projects supports a clear submission aligned with the applicable FBC 2023 and ASCE 7-22 requirements. I will review the provided damage images as part of the technical assessment and focus the documents on the affected balcony and walkway systems rather than the main building. I am ready to prepare a professional, coordinated repair package within your two-week timeframe and provide my engineering expertise for this project. Thanks!
$750 USD in 5 days
0.0
0.0

Hi, I can help review the existing balcony, walkway, and stair conditions and develop structural repair calculations and detailed drawings for the required repairs and replacements. The scope would include concrete slab and cantilever beam repairs, corroded rebar rehabilitation, CMU balcony wall repairs, waterproofing details, and wood and metal railing replacement in accordance with FBC 2023 and ASCE 7-22. **3 key technical questions:** 1. Could you share the required photos of the concrete slabs, balcony damage, and existing railings for an initial assessment? 2. Do you have existing structural drawings, dimensions, and reinforcement details for the balconies and support beams? 3. Will the final calculations and drawings require a Florida-licensed PE stamp, and are there any existing inspection reports? I can review the available documentation, define the repair scope, and work toward your two-week deadline, subject to the extent of the damage and required engineering verification. Best regards! Mark.
$750 USD in 10 days
0.0
0.0

The key here is turning several related defects, spalled balcony concrete, corroded reinforcement, failing wood rails, and metal stair rails, into one coordinated repair set that a contractor can actually build from. Florida wind exposure at 139 mph leaves little room for “close enough” details. I’d organize the work by condition and repair type, then prepare FBC 2023 and ASCE 7-22 calculations for railing loads, wind demands, connections, and affected cantilever elements. Drawings would clearly address concrete removal limits, rebar treatment or replacement, patching, waterproofing, SYP guard replacement, and stair-rail anchorage. That structure should reduce field guesswork and permit-review ping-pong. I’m a licensed P.E. with 12+ years of experience. Send the full image set and available original plans, and I can promptly map out the two-week deliverable sequence. Best regards,
$750 USD in 5 days
0.0
0.0

Hello, no problem. As a licensed engineer, I can help review the existing balcony slabs, support beams, CMU balcony walls, walkway railings, and stair railings to develop a coordinated structural repair and replacement package. I will evaluate the damaged and corroded reinforcement, concrete cracking and spalling, railing connections, and balcony cantilever conditions, with calculations and details based on the applicable 2023 Florida Building Code, ASCE 7-22, and the stated 139 mph wind criteria. The deliverables can include structural repair drawings, reinforcement and concrete restoration details, waterproofing details, SYP wood railing replacement details, metal stair railing details, and supporting structural calculations. Please provide the required photographs of the concrete slabs and railing damage, existing drawings, building location, measurements, and any inspection reports so I can review the actual conditions before confirming the scope. Florida PE registration and sealing authority, along with relevant U.S. project experience and portfolio examples, would need to be confirmed before committing to sealed deliverables. Sincerely, John
$1,000 USD in 3 days
0.0
0.0

Hi, I am a licensed engineer with experience in structural design, concrete repair, reinforcement assessment, railing systems, and permit documentation, and I can help evaluate and develop repair details for your apartment building's balconies, walkways, and stairs. I’ll review the concrete slab, cantilever beams, corroded reinforcement, CMU balcony walls, and existing wood and metal railings to identify the required repairs, reinforcement treatments, replacements, and waterproofing measures. I’ll prepare supporting structural calculations and detailed drawings for the balcony slab and beam repairs, SYP wood railing replacement, and metal stair railing replacement, considering the 2023 Florida Building Code, ASCE 7-22, and the specified 139 mph wind criteria. I understand that you require relevant U.S. project experience and a Florida-authorized PE for the final signed and sealed documents, so I would first confirm the applicable licensure and provide relevant portfolio examples before proceeding. Could you share the concrete slab and railing damage photographs, existing structural drawings, and any inspection reports so I can assess the actual conditions before confirming the scope? Best regards, Justin
$1,000 USD in 3 days
0.0
0.0

Orland, United States
Member since Nov 1, 2017
$30-250 USD
$750-1500 USD
$30-250 USD
$250-750 USD
$250-750 AUD
$250-750 USD
₹1500-3500 INR
$250-750 CAD
$750-1500 USD
$15-25 AUD / hour
$250-750 USD
$250-750 USD
$250-750 AUD
₹600-1500 INR
$250-750 USD
₹750-1250 INR / hour
$250-750 USD
$750-1500 USD
$25-50 CAD / hour
$250-750 USD
$1000 AUD
$250-750 USD
$300-1000 USD
$15-25 USD / hour