Open
Posted
•
Ends in 5 days
Paid on delivery
A new commercial office building is moving from shell condition into full tenant fit-out and the project team now needs a complete lighting strategy—from concept sketches through to construction-ready documentation. The goal is a well-balanced scheme that supports focused work in open plan areas, sets a welcoming tone in the lobby, and meets all relevant energy codes without inflating the electrical load. You’ll be working directly from our architectural plans (DWG/Revit) and will coordinate with the MEP consultant. Preferred tools on our side are Revit 2024, AutoCAD, AGi32 or Dialux for photometrics, and Excel for fixture schedules, so fluency with these will keep the workflow smooth. Key deliverables • Concept layouts with fixture intent and lighting levels • Photometric calculations validating IES recommendations and local code compliance • Fixture schedule specifying make, model, lamp type, wattage, CCT and control notes • Lighting and controls plan sheets ready for the permit set (PDF + native CAD/Revit) • A brief narrative summarising design rationale, energy targets and maintenance strategy Acceptance criteria: average illuminance within ±10 % of the agreed targets, max/min ratios within IES guidelines, and submitted files opening error-free in our software versions. When you reply, focus on your experience with commercial or specifically office interiors—mention at least one completed project of similar scale, the software you used, and any relevant certifications (e.g., LC, LEED, WELL).
Project ID: 40748485
9 proposals
Open for bidding
Remote project
Active 4 hours ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
9 freelancers are bidding on average ₹19,873 INR for this job

Hi, I can deliver your complete office lighting and control strategy, ensuring IES compliance and optimal energy loads. Experience: As an Electrical Power Engineer, I recently executed comprehensive lighting and electrical designs for a large-scale hospital project. Software: I use DIALux evo to guarantee illuminance within your ±10% target, and Revit 2024 / AutoCAD for error-free permit sheets. I will provide all required deliverables: photometric calculations, Excel fixture schedules, native CAD/Revit files, and the design narrative. I am ready to coordinate with your MEP team immediately. Best regards, Karim Mahmoud
₹25,000 INR in 7 days
2.4
2.4

Hi sir, Thank you for your job posting. According to my understanding, you need a complete commercial office lighting package from concept design through permit-ready lighting and controls documentation. We have experience with office and commercial interior lighting design, including open-plan workspaces, reception/lobby areas, meeting rooms, circulation zones, and support spaces. I am comfortable working in Revit 2024 and AutoCAD, with Dialux/AGi32 for photometric analysis and Excel for fixture schedules and load tracking. My workflow includes developing fixture layouts, checking illuminance and uniformity against IES targets, coordinating controls and switching with the MEP team, and keeping connected lighting load within the applicable energy-code limits. I can also prepare detailed fixture schedules with manufacturer/model, wattage, CCT, mounting, and control notes. Final deliverables can include native Revit/DWG files, permit PDFs, photometric reports, fixture schedules, and a concise design narrative covering performance, energy, and maintenance strategy. If you send the architectural model/drawings and project location, I will review everything in detail and confirm the best approach. Looking forward to hearing from you. Thank you.
₹18,000 INR in 5 days
1.6
1.6

Hello, I hope your week is going well. I've spent most of my lighting work on commercial interiors, and office fit-outs are where I feel most at home. Having delivered multiple tenant improvement packages from shell condition through permit, I know how much the MEP coordination piece matters at this stage. One recent project was a four-floor office fit-out where the open plan areas needed even illuminance without glare on monitors. I built the model in Revit 2024 and ran photometrics in AGi32, tuning the layout until average illuminance sat within 5 percent of target and max/min ratios stayed inside IES limits. The fixture schedule lived in Excel with CCT, wattage and control notes tied to each type, which made the contractor's submittal review much quicker. For your building I'd start by reviewing the architectural plans in Revit to confirm ceiling heights and core layout, then build a concept layout with fixture intent before running the first photometric pass. Control zoning would follow the daylight patterns in the open plan areas. Could we hop on a short call to confirm the energy code you're targeting and the CCT direction for the lobby? Those two choices shape the rest of the scheme. Looking forward to hearing from you, Samnang
₹12,500 INR in 50 days
0.0
0.0

I have experience designing industrial systems with precise positioning and feedback, which requires a similar approach to calculations and documentation. I have developed technical documentation for production facilities, including assembly drawings and ventilation calculations. How do you plan to coordinate the lighting scenes between architecture and MEP?
₹12,519 INR in 14 days
0.0
0.0

Hi there, I can design your project "Office Building Lighting Design" with clean, modern, and eye-catching visuals tailored to your brand. Here is what I will do for you: 1. Concept & Direction: Create initial design options based on your brief so you can choose the style you like best. 2. Full Refinement: Polish your chosen design, refine typography, colors, and layout, and make any adjustments you request. 3. Complete Source Files: Deliver all final print-ready and web-ready formats (AI, PSD, PDF, PNG, SVG) along with any fonts used. Zero Risk: You can review the initial design concepts before committing to the final milestone. Quick Question: Do you already have existing brand guidelines, logos, or preferred colors you want used, or should I create a fresh palette for you? Best regards, Ridwaan M
₹13,338 INR in 3 days
0.0
0.0

Hi, taking a commercial space from shell condition to a full tenant fit-out requires a lighting scheme that carefully balances visual comfort, architectural intent, and strict energy codes. Our engineering team specializes in exactly this transition, delivering complete lighting packages that integrate flawlessly with your architectural models and MEP routing. To validate the design, we use AGi32 and Dialux to run rigorous photometric calculations, ensuring average illuminance lands securely within ±10% of your targets and that max/min uniformity ratios strictly follow IES guidelines. From there, we develop the documentation natively in Revit 2024 and AutoCAD to ensure error-free handoffs and clash-free coordination with your MEP consultant. We actively map out daylight harvesting and occupancy controls to optimize your LPD (Lighting Power Density), keeping the electrical load low without sacrificing the welcoming aesthetic of the lobby or the visual acuity needed in the open-plan workspaces. For a recent 30,000 sq ft corporate office fit-out, we successfully handled this exact scope. We utilized Revit and Dialux to deliver the conceptual layouts, permit-ready plan sheets, and a comprehensive Excel fixture schedule detailing make, model, CCT, wattages, and driver notes. As a LEED AP certified team, we are highly experienced in writing clear design narratives that align with aggressive energy targets and maintenance strategies.
₹25,000 INR in 7 days
0.0
0.0

Bengaluru, India
Member since Oct 3, 2026
£10-15 GBP / hour
$10-30 USD
₹600-1500 INR
£20-250 GBP
$5000-10000 USD
₹12500-37500 INR
₹750-1250 INR / hour
$250-750 USD
$30-250 USD
₹1500-12500 INR
$30-250 USD
$25-50 USD / hour
$250-750 USD
₹750-1250 INR / hour
$250-750 AUD
₹750-1250 INR / hour
$3000-5000 USD
₹100-400 INR / hour
$250-750 USD
$15-25 USD / hour